Knob and tube wiring in an Edmonton house is obsolete and ungrounded, and it is often buried under attic insulation it was never designed to touch. It is not automatically a deal breaker, but it needs an electrician's written assessment and an insurance answer before you remove conditions.
Meta description: If your Edmonton house has knob and tube wiring, here is what an inspector can confirm, why insurers ask, and what to fix before you remove conditions.
By Banti K Shaw, InspecUs. I bring more than 10 years of inspection and construction experience to property inspections in Edmonton and surrounding areas.
Did you lift a strip of attic insulation and find a white ceramic knob with a wire wrapped around it? Or did an electrician mention “knob and tube” and leave you unsure whether to panic or shrug?
I’m Banti K Shaw, an InterNACHI-certified home inspector. When I inspect an older home, I focus on what the visible evidence can tell us, what remains concealed, and what you should ask next. For knob and tube wiring, the insurance conversation is often just as important as the electrical assessment.
What are those ceramic pieces actually doing? Knob and tube wiring uses insulated copper conductors that pass through drilled holes in wood framing inside protective porcelain tubes. Along the framing, nailed-down porcelain knobs support the wires. Flexible cloth or rubber “loom” protects wires where they enter a device or pass into a wall.
The system was in common use in North America from about 1880 to the 1940s. It was designed for the electrical needs of its time. Hot and neutral conductors were usually separated by four to six inches, allowing heat to dissipate into free air. Compared with wiring of the same gauge, this arrangement could have higher ampacity. Porcelain components can last a very long time, and original installations often required considerable skill.
That history does not make an old system safe today. As InterNACHI explains, knob and tube wiring is obsolete, but it is “not inherently dangerous”; age, improper modifications, and insulation enveloping the wires are key concerns. No code requires complete removal, although it is not permitted in new construction and jurisdictions treat existing systems differently.
Can a home inspector see every wire in a finished house? No. A home inspection in Edmonton is a visual review of accessible areas, which means finished walls, ceilings and other concealed spaces prevent an inspector from tracing every circuit or confirming whether knob and tube is present behind drywall.
I look for visible evidence in places such as the attic, basement, rim joist, exposed basement ceiling, service area, and behind an open ceiling panel. I can report visible porcelain knobs and tubes, exposed conductors, splices, and nearby insulation. Attics may also reveal other visible concerns, such as air leaks or displaced insulation. See our guide to attic bypasses in Edmonton homes.
InterNACHI advises inspectors to disclaim knob and tube wiring during inspections. A report stating, “Evidence of knob and tube wiring observed at [location]; extent concealed; evaluation by a licensed electrician recommended,” is an accurate report, not a lazy one.
“I report what I can see and name the locations. I will not pretend I can see through drywall or confirm the extent of wiring that is concealed.”
Banti K Shaw, InspecUs
That distinction matters when you read a report. An electrical inspection in Edmonton is a visual check of what is accessible, not a detailed evaluation by a licensed electrician, and the report will say so.
If the wiring is old, what should you focus on? In my experience, three conditions deserve particular attention:

Pro tip: If you see knob and tube under or near attic insulation, avoid disturbing the wiring or insulation yourself. Have a licensed electrician assess it and ask what safe next steps are.
Could a system that once served a modest household safely be expected to handle today’s loads? Not necessarily. Knob and tube wiring was installed when common household appliances included toasters, kettles, and irons. Later homeowners and handymen sometimes tapped modern loads, such as televisions and refrigerators, into existing wiring.
Some people also installed fuses with resistances too high for the wiring so they would not blow as often. That can leave the wiring carrying excessive current and suffering heat damage instead of having a fuse interrupt the circuit as intended.
Knob and tube has no grounding conductor, so it cannot serve three-pronged appliances as a grounded system. InterNACHI also advises against using it in kitchens, bathrooms, laundry rooms, or outdoors, where grounding is required for safe use.
Is knob and tube a repair issue or an insurance issue? It can be both, but your insurer decides what coverage it will offer for your specific property.
The Insurance Bureau of Canada (IBC) notes that pre-war homes commonly have knob and tube wiring. It has no ground wire, and rubberized cloth insulation can deteriorate and expose the wire, potentially increasing fire and shock risk. IBC advises you to contact your insurance representative if the wiring is confirmed. Some carriers may require an updated certificate to maintain coverage.
InterNACHI says many insurers refuse to insure homes with knob and tube, while exceptions are sometimes made when an electrical contractor has deemed the system safe. Insurers vary. Some may decline, while others may ask for an electrician’s assessment or other documentation. Only your own insurer or broker can answer for your file.
IBC’s article is national consumer guidance and refers to Ontario’s Electrical Safety Authority. Alberta’s permit and inspection path is different. For more on the connection between inspections and insurance questions, see our article on home inspections and Edmonton insurance.
“I tell buyers to make the insurance call early. That conversation is often the one that decides the deal, so I recommend having it before conditions are removed.”
Banti K Shaw, InspecUs
If an electrician recommends changes, do you need a permit? Under Alberta’s Safety Codes Act and Permit Regulations, a permit is required to install, alter, or add to an electrical system. Edmonton is an accredited municipality and administers its own electrical permits and inspections. Outside an accredited municipality, permits and inspections are handled by an accredited agency on behalf of the Alberta Safety Codes Authority. Check the Safety Codes Council permit information or your municipality for your location.
The City of Edmonton’s electrical permit page says a homeowner permit is only available to someone who owns and lives in a single-family dwelling and does the work themselves. Permits are not issued for rental properties, apartment-style condos, stacked homes, semi-detached homes, or row housing. The City also says permits will not be issued where wiring is concealed, such as behind boarded or drywalled walls.
Homeowners who are not certified master electricians cannot install or relocate the main service panel or service equipment, do pool grounding, or install solar PV. The City currently lists a homeowner minor alterations fee of $160 plus a $6.40 safety codes fee. Inspections must be requested. If required inspections are missed, finished walls may need to be removed, adding cost and delay.
InspecUs provides inspections and reporting, not electrical work, permits, or repairs. Confirm requirements with your municipality or the Alberta Safety Codes Authority before work begins.
Does seeing knob and tube mean you should walk away? Not automatically. Plenty of Edmonton homes with knob and tube are lived in safely every day. That is exactly why a written assessment matters more than rumours.
You can ask a licensed electrician to assess the visible system, describe what appears modified, state whether the electrician considers it safe to keep, and outline what a rewire would involve. Use that assessment to negotiate if appropriate. You can also budget for a rewire as a possibility: InterNACHI notes rewiring can take weeks and cost thousands of dollars. Or you may decide the property is not right for you.
A comprehensive pre-purchase home inspection in Edmonton can help you understand what is visible before you make that decision.
What would help you move from uncertainty to a practical decision? Ask these questions and keep the answers in writing:

If you are weighing the inspection findings against your purchase deadline, read about removing home inspection conditions in Alberta.
No code requires complete removal. It is not permitted in new construction, and jurisdictions treat existing installations differently. Replacement decisions depend on the wiring’s condition, modifications, and your insurer’s requirements.
No. A home inspector can report visible evidence in accessible areas, but cannot confirm or rule out wiring concealed behind finished walls or ceilings.
It depends on the insurer and property. Some carriers refuse coverage; some may make exceptions based on a contractor’s assessment or request other documentation. Ask your broker before removing conditions.
It can narrow the buyer pool and affect financing or insurance considerations, so it may come up in negotiations. The effect depends on the property and buyer, and there is no reliable percentage or fixed dollar amount that applies to every home.
If you are considering an older Edmonton house, you do not need to make a decision based on fear or an assumption about what is behind the walls. Start with an honest account of visible evidence, then get an electrician’s written assessment and confirm the insurance requirements for your specific property.
If you want a clear read on what is visible, you can contact InspecUs to book a home inspection. There is no pressure; it is a practical next step toward making an informed decision.
We are licensed by the Licensed Professional and certified through InterNACHI
InspecUs Home Inspection is certified in the best practices established by Internachi. Our commitment to safety includes maintaining a 6-foot distance and using personal protective equipment (PPE) during all inspections.